EGGER OS'Floor may be used over wood products or metal floor framing systems. For best results with wood product frames, deep floor joists (150mm or more) should be seasoned and gauged. Floor joists shall be securely fixed to bearers. Top edges of the joists must be correctly aligned to provide a flat level surface.
The span information and nail grid should always face upwards. Panels shall be laid with stacked end joints (brickwork pattern) – no cross joins are permitted.
The individual sheet lengths should cover at least two floor joist spaces. If single span cut-in-panels are required, a trimmer (min. 70 x 35mm) must be fixed between the joists to support the middle of the panel.
Construction grade adhesive should be applied to the upper surface of joist members prior to sheet placement (see Use of Adhesive).
EGGER OS'Floor will withstand up to 3 months outdoor exposure without effecting the structural performance. However, whenever possible, exposure to the elements should be limited by suitable measures and the panels should be covered as soon as possible.
EGGER OS'Floor properties may be affected by moisture saturation and/or exposure to sub-zero temperatures. During the exposed period, do not allow water to pond on the surface. Remove water by sweeping and drilling small holes (Ø 6mm) adjacent to plate lines. Do not directly cover panels with sheeting or apply liquid sealers to avoid moisture trapping.